Ambient air quality monitor system AQM 09

Product Introduction

  • 110CM*70CM*40CM
  • SO2, CO, O3, NO2, PM2.5, PM10, TSP
  • Temperature, humidity, Wind direction, Wind speed,
  • Air pressure, Noise

Solid Structure Design

  • 1.2mm Industrial Grade Cold rolled carbon steel;
  • Pickling and rust-proof treatment; anti-corrode, not afraid of acid rain/oil/stains;
  • Bright/clean surface; no rust; no pulverization;
  • IP55 grade dustproof and waterproof design.
  • Main body adopts seamless welding/solid structure;
  • Two sides dust cover(ventilation, heat dissipation, dustproof, waterproof).

Installation Convenience

  • International standard Aluminium back beam;
  • With anchor ear so it is convenient for wall mounitng and pole installation;
  • Reliable and stable installation method;

Reference Standard

  • HJ 654-2013, Environmental pollution gas(SO2、 NO2、 CO、 O3)Technical requirements and testing methods of continuous automatic monitoring system
  • HJ_T 212-2017 Pollutant on-line monitoring system data transmission standard;
  • HJ_T 524-2009 Air pollutant code;
  • HJ663-2012 Ambient air quality index(AQI) Technical regulation;
  • GB/T 19582-2008 Based on Modbus,Industrial automation network specification;

Modular Design

  • Wireless Transmission Module
  • Power Supply Module
  • PM Acquisition Module
  • Gas Monitoring Module
  • PM Monitoring Module
  • Temperature/RH Monitoring Module
  • Display Module

  • Industrial Grade Earth leakage circuit breaker;
  • Cold and heat resistance;
  • Short circuit, overload and leakage protection;
  • High performance switching power supply;
  • Low ripple output; Constant current overcurrent protection;
  • Self-recovery of short circuit protection;
  • Over voltage protection;
  • Solar power supply system(optional);

Function

Touch Screen

  • High-definition display:
  • 5.0 inch;
  • 800*480 resolution;
  • Backlight life>20000h;
  • Working temperature: -20℃ ~ 50℃;
  • Touch Number: 800,000 times;

 

Data transmission

  • 4G LTE/GPRS/WIFI:
  • Integrated terminal data transmission;
  • Support multiple up and down trigger modes;
  • Support remote management, high efficiency;
  • SMS backup;
  • Equipped with high gain antenna, not affect the data transmission;
  • Cloud platform terminal monitoring data real-time;

 

Sampling Probe

The pump are made of high quality hard aluminum alloy 6061 through sand blasting and oxidation treatment, with good corrosion resistance and smooth surface roughness. Convenient and quick disassembly and assembly structure, convenient for users to clean the catch plate.

 

Weight About 1kg
Dimension 230mm*φ45mm
Sampling system matching requirements Sampling Flow 1.3L/Min±0.15
Cut Size PM2.5,PM10
Interface Size Φ6 Flexible Hose

 

High Precision Dust Sensor

 

 

 

 

PM parameter Technical Index
Detecting Range PM2.5: (0-2000)ug/m3

PM10: (0-2000)ug/m3

Sampling Flow 1.3L/min, precision±0.15
Sampling Time Adjustable/5min
Partical Size PM2.5,PM10,TSP
LOD 2ug/m3
Resolution 1ug/m3
Dehumidification

Method

Air intake dynamic heating dehumidification system

heating time can be set, PID adjustment method, with humidity detection, can reduce energy consumption

 

Temperature/Humidity detection

  • Industrial Grade Temperature/Humidity sensor;
  • Humidity Error 3%;
  • Humidity 0.5℃;
  • 3.2uW power consumption;
  • Temperature Range:-40 ~ 120℃;
  • Humidity Range:0-100%RH;
  • Using RS485 industrial communication interface, stable and reliable.

 

Import Alpha B4 series sensor

  • Imported high precision Electrochemical sensor;
  • B4 series Environmental air quality professional sensor;
  • Response quickly;
  • Strong anti-interference ability;
  • High resolution;
  • Excellent linearity;
  • More than 2 years life;
Gas factor technical  parameters Detecting Range/ppb Resolution /ppb Detection limit /ppb Precision/%FS
Ozone(O3) 1000 1 3 ±5
  Nitrogen dioxide(NO2) 1000 1 3 ±5
Sulfur dioxide(SO2) 1000 1 3 ±5
Carbon monoxide(CO) 100ppm 0.1ppm 0.3ppm ±3

 

Cloud platform real-time data and curve display

 

 

 

 

Application

Urban Environmental Air Quality Monitoring Grid

 

Heavy Industry Petrochemical Industry Mining yard Agricultural Straw Burning
Tourist Attractions Residential Community School Hospital


Features

 

  • Dynamic heating dehumidification system can minimize the influence of humidity on particulate matter;
  • Through the actual test, when the air humidity reaches 95%RH in this system, the error of monitoring value and state control point is within 20%;
  • The error can be further reduced by comparing with the multi-point calibration of the state control point;
  • Cooperate with humidity monitoring, adjust the heat dehumidification module in real time, furtherReduce system running power;
  • Imported 4 electrode sensor for environmental air quality,respond quickly;
  • Strong anti-interference ability; High resolution(ppb Grade); Wide work range;
  • The data acquisition system uses 32-bit high performance industrial-level processors,with 16-bit high resolution ADC enables the sensor to perform more effectively;

 

Product Name Ambient air quality monitor system
Product Mode AQM-09
Sampling Mode Difusion/Pump-suction Mode
Data transmission RS485 Modbus, 4G, WIFI, GPRS
Preheating Time 60s
Body Material Cold Rolled Steel Plate
Istallation Method Column/wall mounted(optional)
Working 

Temperature

-20℃–50℃
Working Humidity 10%RH -95%RH
Storage Temperature -40℃–80℃
Power Supply AC220V/50Hz/Solar power(optional)
Overall Power

Consumption

<20W(Humidity<90%RH);

<40W(Humidity>90%RH),

Dimension 110*70*40cm
Protection Grade IP55 Dustproof/Waterproof