The gas mass flowmeter features 2% of reading accuracy across a wide flow range and provides independent mass flow readings of temperature and pressure. It is easy to operate and configure measurements with its device settings. Comes with a 0 to ±30 Std L/min range and is calibrated for Air, O2 and N2. Up to 4 readings can be viewed simultaneously from the gas mass flowmeter's color touchscreen display.
The gas mass flowmeter features 2% of reading accuracy across a wide flow range and provides independent mass flow readings of temperature and pressure. It is easy to operate and configure measurements with its device settings. Comes with a 0 to ±30 Std L/min range and is calibrated for Air, O2 and N2. Up to 4 readings can be viewed simultaneously from the gas mass flowmeter's color touchscreen display.
The gas mass flowmeter features 2% of reading accuracy across a wide flow range and provides independent mass flow readings of temperature and pressure. It is easy to operate and configure measurements with its device settings. Comes with a a 0 to ±30 Std L/min range and is calibrated for Air, O2 and N2. Up to 4 readings can be viewed simultaneously from the gas mass flowmeter's color touchscreen display.
Features
Applications
Range | 0 to ±30 Std L/min |
Accuracy | 2% of reading |
Calibration | Air, O2, N2 |
Response | 4 ms to 63% of full scale |
Power | Supplied through USB-C port 5.0 VDC ±5%, 500 mA maximum |
Burst Pressure | Tested to 690 kPa without rupture; DO NOT exceed 690 kPa |
Digital Output | USB, RS-232 serial using an optional USB-A to RS-232 converter cable |
Display | 2.8" (7 cm) color LCD touchscreen |
Internal Storage | 1 GB storage, max 20 datalog files |
Material | Polycarbonate (flow body) |
Click on a category to view a selection of compatible accessories with the TSI/Alnor 5200-2 Gas Mass Flowmeter with kit, Air, O2, N2, 0 to ±30 Std L/min.
Range | 0 to ±30 Std L/min |
Accuracy | 2% of reading |
Calibration | Air, O2, N2 |
Response | 4 ms to 63% of full scale |
Power | Supplied through USB-C port 5.0 VDC ±5%, 500 mA maximum |
Burst Pressure | Tested to 690 kPa without rupture; DO NOT exceed 690 kPa |
Digital Output | USB, RS-232 serial using an optional USB-A to RS-232 converter cable |
Display | 2.8" (7 cm) color LCD touchscreen |
Internal Storage | 1 GB storage, max 20 datalog files |
Material | Polycarbonate (flow body) |
Click on a category to view a selection of compatible accessories with the TSI/Alnor 5200-2 Gas Mass Flowmeter with kit, Air, O2, N2, 0 to ±30 Std L/min.